{"product_id":"schneider-three-phase-energy-meter","title":"Schneider Three Phase Energy Meter","description":"\u003cdiv class=\"first:-mt-sm mb-4 mt-5\"\u003e\n\u003cdiv class=\"gap-sm scrollbar-none px-md -mx-md relative flex flex-row overflow-x-scroll md:mx-0 md:overflow-x-visible md:px-0\"\u003e\n\u003cdiv class=\"relative w-[120vw] shrink-0 md:w-full\"\u003e\n\u003cdiv class=\"flex w-full\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pl-md pr-sm pointer-events-none relative z-[1] flex items-center justify-end md:absolute md:inset-0 md:px-0\"\u003e\n\u003cdiv class=\"font-sans text-base text-foreground selection:bg-super\/50 selection:text-foreground dark:selection:bg-super\/10 dark:selection:text-super\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"tabler-icon tabler-icon-chevron-right tabler-icon\"\u003e\u003cpath d=\"M9 6l6 6l-6 6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"my-2 first:mt-0 [\u0026amp;:has([data-inline-type=image])+\u0026amp;:has([data-inline-type=image])_[data-inline-type=image]]:hidden [\u0026amp;:has(table)_[data-inline-type=image]]:hidden [\u0026amp;_h1:first-of-type]:mt-8 [\u0026amp;_h2:first-of-type]:mt-6\"\u003e\n\u003cdiv class=\"relative\"\u003e\n\u003cdiv class=\"prose text-pretty dark:prose-invert inline leading-relaxed break-words min-w-0 [word-break:break-word] prose-strong:font-medium\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eSchneider Electric offers a range of high-quality\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThree Phase Energy Meters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for industrial, commercial, and utility applications, providing accurate measurement, data logging, and advanced energy management features.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0\"\u003eKey Models and Specifications\u003c\/h2\u003e\n\u003cdiv class=\"group relative\"\u003e\n\u003cdiv class=\"w-full overflow-x-auto md:max-w-[90vw] border-subtlest ring-subtlest divide-subtlest bg-transparent\"\u003e\n\u003ctable class=\"border-subtler my-[1em] w-full table-auto border-separate border-spacing-0 border-l border-t\"\u003e\n\u003cthead class=\"bg-offset\"\u003e\n\u003ctr\u003e\n\u003cth class=\"border-subtler p-sm break-normal border-b border-r text-left align-top\"\u003eModel\u003c\/th\u003e\n\u003cth class=\"border-subtler p-sm break-normal border-b border-r text-left align-top\"\u003eVoltage\u003c\/th\u003e\n\u003cth class=\"border-subtler p-sm break-normal border-b border-r text-left align-top\"\u003eCurrent Range\u003c\/th\u003e\n\u003cth class=\"border-subtler p-sm break-normal border-b border-r text-left align-top\"\u003eAccuracy Class\u003c\/th\u003e\n\u003cth class=\"border-subtler p-sm break-normal border-b border-r text-left align-top\"\u003eCommunication\u003c\/th\u003e\n\u003cth class=\"border-subtler p-sm break-normal border-b border-r text-left align-top\"\u003eKey Features\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eiEM3250 (A9MEM3250)\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003e100-440V AC\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003e1A\/5A CT operated\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eClass 0.5s\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eModbus RTU (RS485)\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eTrivector measurement, bidirectional, energy and power logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eiEM3000 series\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003e100-480V AC\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eDirect connect up to 63A\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eClass 1\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003ePulse output, Modbus, M-Bus\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003ePower quality, multi-tariff, load profile data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eiEM2050 (A9MEM2050)\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003e230V\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eUp to 63A\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eClass 1\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eModbus RTU\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eActive\/reactive energy, LCD display, compact size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eEM6433\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003e415V\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eCT operated\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eClass 1\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eOptical interface\u003c\/td\u003e\n\u003ctd class=\"px-sm border-subtler min-w-[48px] break-normal border-b border-r\"\u003eHigh precision metering, energy \u0026amp; power quality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"px-two bg-base border-subtler shadow-subtle pointer-coarse:opacity-100 right-xs absolute bottom-0 flex gap-2 rounded-lg border py-px opacity-0 transition-opacity group-hover:opacity-100\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0\"\u003eCommon Features\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypically 100–480 VAC for three-phase systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eCurrent:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDirect connection or CT-operated, accommodating 1A or 5A secondary CTs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh accuracy (Class 0.5s or Class 1) per IEC\/IS standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eDisplay:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBacklit LCD for multi-parameter viewing with scrolling features.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eCommunications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModbus RTU (RS485), Optical port, Pulse output, M-Bus for remote reading and integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMeasurement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTrue 3-phase trivector measurement (active\/reactive\/apparent energy), power factor, maximum demand, load profile logs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eAdvanced Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupport for multi-rate tariffs, net metering (import\/export), event logging, and tamper detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN rail for easy panel installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"UrjaPoint Electrical's Pvt. Ltd. Powered by Arvizon Global Enterprises Pvt. Ltd.","offers":[{"title":"240V \/ 5-30 A","offer_id":42707555025105,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"240V \/ 10-40 A","offer_id":42707555057873,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"240V \/ 20-100 A","offer_id":42707555090641,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"240V \/ 1 A","offer_id":42707555123409,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"240V \/ 5 A","offer_id":42707555156177,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"415V \/ 5-30 A","offer_id":42707555188945,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"415V \/ 10-40 A","offer_id":42707555221713,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"415V \/ 20-100 A","offer_id":42707555254481,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"415V \/ 1 A","offer_id":42707555287249,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"415V \/ 5 A","offer_id":42707555320017,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"11KVA \/ 5-30 A","offer_id":42707555352785,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"11KVA \/ 10-40 A","offer_id":42707555385553,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"11KVA \/ 20-100 A","offer_id":42707555418321,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"11KVA \/ 1 A","offer_id":42707555451089,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"11KVA \/ 5 A","offer_id":42707555483857,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0656\/4039\/9057\/files\/a1ae5bb0-9c73-5189-9e36-292bdc04a608_2.jpg?v=1756458254","url":"https:\/\/urjapoint.com\/products\/schneider-three-phase-energy-meter","provider":"UrjaPoint Electricals powered by Arvizon Global Enterprises Pvt. Ltd.","version":"1.0","type":"link"}