{"product_id":"l-t-lt-ct-energy-meter-copy","title":"Schneider LT CT Energy Meter","description":"\u003cdiv class=\"first:-mt-sm mb-4 mt-5\"\u003e\n\u003cdiv class=\"gap-sm scrollbar-none px-md -mx-md relative flex flex-row overflow-x-scroll md:mx-0 md:overflow-x-visible md:px-0\"\u003e\n\u003cdiv class=\"relative w-[120vw] shrink-0 md:w-full\"\u003e\n\u003cdiv class=\"flex w-full\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pl-md pr-sm pointer-events-none relative z-[1] flex items-center justify-end md:absolute md:inset-0 md:px-0\"\u003e\n\u003cdiv class=\"font-sans text-base text-foreground selection:bg-super\/50 selection:text-foreground dark:selection:bg-super\/10 dark:selection:text-super\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"tabler-icon tabler-icon-chevron-right tabler-icon\"\u003e\u003cpath d=\"M9 6l6 6l-6 6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"my-2 first:mt-0 [\u0026amp;:has([data-inline-type=image])+\u0026amp;:has([data-inline-type=image])_[data-inline-type=image]]:hidden [\u0026amp;:has(table)_[data-inline-type=image]]:hidden [\u0026amp;_h1:first-of-type]:mt-8 [\u0026amp;_h2:first-of-type]:mt-6\"\u003e\n\u003cdiv class=\"relative\"\u003e\n\u003cdiv class=\"prose text-pretty dark:prose-invert inline leading-relaxed break-words min-w-0 [word-break:break-word] prose-strong:font-medium\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eSchneider Electric offers a range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLT CT (Low Tension, Current Transformer) Energy Meters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for high-accuracy energy measurement in three-phase, four-wire systems where the current is measured via external CTs. These meters are widely used in industrial, utility, and commercial applications requiring reliable billing, energy monitoring, and data logging.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0\"\u003eKey Features and Specifications of Schneider LT CT Energy Meters:\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMeasurement Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThree-phase, four-wire LT CT-operated energy meters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypically 415V AC (Phase-to-Phase), 230V AC (Phase-to-Neutral)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-\/5A CT secondary current input (some models support 1A or 10A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eAccuracy Class:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass 0.5S (active and reactive energy), compliant with IEC 62053-22\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eDisplay:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBacklit LCD showing active energy (kWh), reactive energy (kVARh), apparent energy (kVAh), voltage, current, power factor, frequency, maximum demand, and load profiles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModbus RTU (RS485), M-Bus, pulse outputs, and optical interface for remote data acquisition and integration with AMI\/SCADA systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eData Logging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLoad survey capable, with up to 90 days of 15-minute interval data storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTariff Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultiple tariff rates, time-of-day metering, demand and block energy measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTamper Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes detection for phase loss, current reversal, tampering attempts, cover opening, and magnetic interference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-10°C to +55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIEC 62052-11, IEC 62053-22, IS 15959, IS 14697, and DLMS\/COSEM for communication protocols\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN rail mountable with compact dimensions suitable for panel installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0\"\u003ePopular Models:\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eiEM3250:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCT-operated, Modbus RTU communication, Class 0.5s accuracy, supports advanced features like multi-tariff, demand, and energy quality monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eiEM3215:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMulti-tariff CT meter suitable for integrated smart metering solutions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eiEM3200:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSub-billing and partial measured energy applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"UrjaPoint Electrical's Pvt. Ltd. Powered by Arvizon Global Enterprises Pvt. Ltd.","offers":[{"title":"240V \/ 5-30 A","offer_id":42707556892881,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"240V \/ 10-40 A","offer_id":42707556925649,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"240V \/ 20-100 A","offer_id":42707556958417,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"240V \/ 1 A","offer_id":42707556991185,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"240V \/ 5 A","offer_id":42707557023953,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"415V \/ 5-30 A","offer_id":42707557056721,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"415V \/ 10-40 A","offer_id":42707557089489,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"415V \/ 20-100 A","offer_id":42707557122257,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"415V \/ 1 A","offer_id":42707557155025,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"415V \/ 5 A","offer_id":42707557187793,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"11KVA \/ 5-30 A","offer_id":42707557220561,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"11KVA \/ 10-40 A","offer_id":42707557253329,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"11KVA \/ 20-100 A","offer_id":42707557286097,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"11KVA \/ 1 A","offer_id":42707557318865,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true},{"title":"11KVA \/ 5 A","offer_id":42707557351633,"sku":null,"price":599.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0656\/4039\/9057\/files\/32c52ecb-4c9f-582f-85d5-23f691d2201b.jpg?v=1756461441","url":"https:\/\/urjapoint.com\/products\/l-t-lt-ct-energy-meter-copy","provider":"UrjaPoint Electricals powered by Arvizon Global Enterprises Pvt. Ltd.","version":"1.0","type":"link"}